Сеткавы адаптар CompactLogix Modbus TCP C4374
Get Latest Price| мінімум заказ: | 1 |
мадэль №: C4374
| спампаваць | : |
|
The file is encrypted. Please fill in the following information to continue accessing it
| General parameters | |
| System Power |
Power supply: 19.2-28.8VDC (Nominal: 24VDC)
Protection: anti-reverse protection
|
| Power Consumption | 135mA@24VDC |
| Internal Bus Supply Current | Max.2.0A@5VDC |
| Isolation | System power to field power: isolated |
| Field Power | Power supply: 19.2-28.8VDC(Nominal: 24VDC) |
| Field Power Current | Max. DC 8A |
| Number of Supported I/O Modules | 32 |
| Wiring | Max.1.5mm² (AWG 16) |
| Installation: | 35mm DIN-Rail |
| Size | 115*102*82mm |
| Weight | 302g |
| Environmental parameters | |
| Operating Temperature of Vertical Installation | -20℃~60℃ |
| Operating Temperature of Horizontal Installation | -20℃~50℃ |
| Relative Humidity | 5%~95%RH (no condensation) |
| Storage Temperature | -40℃~85℃ |
| Storage Humidity | 5%~95%RH (no condensation) |
| Ingress Protection Rating | IP20 |
| EMC Specifications | Comply with IEC61131-2, IEC61000-4 |
| Environmental parameters | |
| Programming Software | Codesys V3.5.19.70 |
| Programming Language | IEC61131-3(LD、IL、ST、CFC/FBD、SFC) |
| Maximum Task Status | 5 |
| Program Memory | 4M Bytes |
| Data Storage | 4M Bytes |
| Power-down Protection Area | 3.9K Bytes |
| Maximum Expansion Module Input | 1K Bytes |
| Maximum Expansion Module Output | 1K Bytes |
| Bitwise Operations Cycle | 0.10us |
| Word Operation Cycle | 0.10us |
| Double Word Operation Cycle | 0.27us |
| Minimum Program Run Cycle | 1ms |
| RTC | Supported (external battery required) |
| Communication parameters | |
| Communication interface | 3*RJ45,1*RS485,1*CAN |
| Network protocols | Modbus RTU, Modbus TCP, EtherCAT, CANOpen |
| Network port parameters | 10/100Mbps Adaptive, full-duplex |
| RS485 Interface parameters | 2400~115200bps |
| CAN Interface parameters | 10K~1000K bps |
| Modbus TCP Client | A maximum of 5 Modbus TCP server connections are supported |
| Modbus TCP Server | A maximum of 5 Modbus TCP client connections are supported |
| Modbus RTU Master | A maximum of 5 slave devices can be connected |
| Modbus RTU Slave | Supported |
| EtherCAT | A maximum of 32 EtherCAT slave devices can be connected |
| CANOpen | A maximum of 8 CANOpen slave devices can be connected |